<LOGO>
FM Transmitter Measurement Report
Created: 2025-02-12 11-52-40
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
97.40 MHz 4/5, 48 dBuV RIRE &
Pilot RDS Phase Difference
7.3 kHz 4.8 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
18 kHz 73 kHz 8615 39,3500
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,0 dBr
MIN AVE MAX % above 10,0 dBr
4,3 dBr 6,40 dBr 7,8 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" RIRE & " F226 0 (No PTY) 1 0 1 2 11:52, 12.02.2025
RT
"RIRE : MANU PAYET "
AF EON
91.4, 92.0, 92.1, 94.4, 95.4, 96.2, 97.3, 97.4, 97.5, 97.6, 103.3, 104.4, 107.3 MHz -
FM Scope Station: 97.40 MHz, signal: 4/5 (52 dBuV) Max at: 73 kHz MIN: 18 kHz % above 75 kHz: 39,3500 Acquired: 2025/02/12 11:51:37 Total samples: 8615 Equivalent time: 0:07:10 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 7,8 dBr MIN: 4,3 dBr AVE: 6,40 dBr % above 10,0 dBr: 0,0 Last value: 4,9 dBr (2025/02/12 11:51:36) Station: 97.40 MHz, signal: 4/5 (48 dBuV) 11:45 11:46 11:47 11:48 11:49 11:50 11:51 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality